BL A C K B O X
®
Find problems in copper cables.
EZ Check Cable Tester with Probe
EZCTP
Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S.
call 724-746-5500) FREE technical support 24 hours a day, 7 days a
week: Call 724-746-5500 or fax 724-746-0746 Mailing address:
Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018
Web site: www.blackbox.com • E-mail: [email protected]
Customer
Support
Information
NOM Statement
724-746-5500 | blackbox.com
EZCTP
Normas Oficiales Mexicanas (NOM)
Electrical Safety Statement
INSTRUCCIONES DE SEGURIDAD
1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado.
2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura.
3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben
ser respetadas.
4. Todas las instrucciones de operación y uso deben ser seguidas.
5. El aparato eléctrico no deberá ser usado cerca del agua por ejemplo, cerca de la tina de baño, lavabo, sótano
mojado o cerca de una alberca, etc.
6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales que sean recomendados por el fabricante.
7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recomendado
por el fabricante.
8. Servicio El usuario no debe intentar dar servicio al equipo eléctrico más allá lo descrito
en las instrucciones de operación. Todo otro servicio deberá ser referido a personal de
servicio calificado.
9. El aparato eléctrico debe ser situado de tal manera que su posición no interfiera
su uso. La colocación del aparato eléctrico sobre una cama, sofá, alfombra o superficie similar puede bloquea la
ventilación, no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilación.
10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores, registros de calor, estufas
u otros aparatos (incluyendo amplificadores) que producen calor.
11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en
el instructivo de operación, o como se indique en el aparato.
12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo
no sea eliminada.
13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos
colocados sobre o contra ellos, poniendo particular atención a los contactos y receptáculos donde salen del aparato.
14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las recomendaciones del fabricante.
15. En caso de existir, una antena externa deberá ser localizada lejos de las lineas de energia.
16. El cable de corriente deberá ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo.
17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre
la cubierta u orificios de ventilación.
18. Servicio por personal calificado deberá ser provisto cuando:
A: El cable de poder o el contacto ha sido dañado; u
B: Objectos han caído o líquido ha sido derramado dentro del aparato; o
C: El aparato ha sido expuesto a la lluvia; o
D: El aparato parece no operar normalmente o muestra un cambio en su desempeño; o
E: El aparato ha sido tirado o su cubierta ha sido dañada.
FCC Statement
724-746-5500 | blackbox.com
EZCTP
FEDERAL COMMUNICATIONS COMMISSION AND
INDUSTRY CANADA RADIO FREQUENCY INTERFERENCE STATEMENTS
This equipment generates, uses, and can radiate radio-frequency energy, and if not installed and used
properly, that is, in strict accordance with the manufacturer’s instructions, may cause inter ference to radio
communication. It has been tested and found to comply with the limits for a Class A computing device in
accordance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reasonable
protection against such interference when the equipment is operated in a commercial environment. Operation of
this equipment in a residential area is likely to cause interference, in which case the user at his own expense will
be required to take whatever measures may be necessary to correct the interference.
Changes or modifications not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
This digital apparatus does not exceed the Class A limits for radio noise emis sion from digital apparatus set
out in the Radio Interference Regulation of Industry Canada.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux
appareils numériques de la classe A prescrites dans le Règlement sur le brouillage radioélectrique publié par
Industrie Canada.
© Copyright 2011. Black Box Corporation. All rights reserved. Black Box
®
and the Double Diamond
logo are registered trademarks of BB Technologies, Inc. Any third-party trademarks appearing in
this manual are acknowledged to be the property of their respective owners.
FREE! Live, 24/7 Tech Support is just 30 seconds away.
724-746-5500 | blackbox.com
EZCTP, rev. 2
Chapter 3: Connecting to the Tester
724-746-5500 | blackbox.com
Page 2
EZCTP
Figure 3-1 (right). Testing installed cables.
Remove the remote and connect it
to the far end of the cable.
To test patch cables: Attach the main unit and remote
directly to the cable ends, as shown in Figure 3-2.
Figure 3-2 (right). Testing patch cables: Slide the remote
to the side to expose the RJ-45 port and connect the cable
to the connector.
To test coax cables: Coax is displayed using the 4&5 LEDs.
The coax terminator is in the zippered nylon storage pouch.
4. Using the EZCT
Power ON and test:
STEP 1: Press the ON button to turn the
unit on. Press it again to begin a test.
STEP 2: When the PASS/FAIL LEDs
light, press the FAULT CHECK button
to isolate any problems to an individual
pair.
Figure 4-1 (right). The EZCT faceplate.
Chapter 4: Using the EZCT
724-746-5500 | blackbox.com
Page 3
EZCTP
Key to Failure Descriptions:
OPEN: A wire is disconnected.
SHORT: A wire makes contact
with another wire.
CROSS (REVERSAL): A twisted
pair is not properly connected
on one end of the cable.
SPLIT: One wire from each of the
two different pairs is not properly
connected on both ends of the
cable.
Chapter 5: Tone mode
724-746-5500 | blackbox.com
Page 4
EZCTP
Chapter 1: Features
724-746-5500 | blackbox.com
Page 1
EZCTP
1. Features
• Tests both RJ-45 CAT5/6 and coax cables.
• Ruggedized for field use. Small and easy to carry.
• PASS/FAIL results appear in one second.
• Each pair’s status is highlighted.
Performs complete TIA568 test: continuity; opens/shorts; reversals;
split pairs.
• Tone mode for tracing cables and troubleshooting.
• Auto-off (12 seconds) to conserve battery life.
• Low battery indicator.
• Belt clip, battery (9V), and pouch included.
2. What‘s included
• Test unit with built-in remote
• 12" RJ-45 cable
• 4.5" BNC male to BNC male patch cable
• Coax terminator
• Belt clip (removable)
• Nylon zipper storage pouch
• Black Box Lighted Probe
• 9-volt battery
• (1) RJ-45 to (2) alligator clips cable assembly
• This user‘s manual
3. Connecting Cables to the Tester
Ethernet cables have 4 pairs of wires (“pairs“ or ”twisted pairs”). It is important
that the pairs correctly go to connector pins 1–2; 36; 45; and 7–8. The EZ
Check Cable Tester tests for the proper pairing; if there is an error it will report
it to you (split pairs”) via LED signals on the easy-to-understand faceplate.
To test installed cables: Connect the main unit to the wall jack and the remote
to the patch panel or far-end wall jack, as shown in Figure 3-1.
A tone is placed on the cable by the EZ Check
Cable Tester main unit. A separate probe locates
the tone at the far end of the cable.
Connect the cable: Plug the cable into the tester’s
main unit.
Power ON and tone: Press the ON button. Hold
the TONE button for 7 seconds to turn on the
tone. Press the TONE button repeatedly to select
the pair you wish to tone. Select the setting that
provides the loudest tone.
The tone is loudest when you select the entire cable (including the shield).
5. Tone Mode
Figure 4-7. The EZCT uses LED 4&5 to display the
status of a coax cable test. Connect the near end
of the cable to the BNC connector. Connect the
far end to the coax terminator (found in the
zippered nylon storage pouch). The illustration at
right indicates a good cable connection.
Figure 4-2. This indicates no failure on a
good cable. Everything is normal.
Figure 4-6. There are crossed wires on
both pairs 45 and 7–8.
Figure 4-5. There is a short on pair 36.
Figure 4-4. There is a split, or improper
connections, on pairs 1–2 and 36.
Figure 4-3. There is an opening,
or a broken cable, on pair 1–2.
Figure 5-1. Tone is used
to locate the far end of
the cable.
Identify breaks, shorts, splits,
and cross-circuits in UTP and
coax cables at a glance.
Chapter 6: Using the Probe
6.0 Using the Probe
The filtered probe detects the tone from the main EZCT unit.
Ultrabright LED shines from the tip of
the probe
Volume control is on the back of the
probe
Press to activate the probe’s circuitry
and light the ultrabright LED on the
tip
The “Tone” LED is a visual indication
that the tone is detected
“60HZ” LED warns that 60Hz (VAC)
is present and should be avoided
9-volt battery
Warranty and Return Information
If you determine that your EZCTP is malfunctioning, do not attempt to alter or repair
the unit. It contains no user-serviceable parts. Contact Black Box Technical Support
at 724-746-5500 or info@blackbox.com.
Before you do, make a record of the history of the problem. We will be able to
provide more efficient and accurate assistance if you have a complete description,
including the nature and duration of the problem, when the problem occurs, and
any particular application that, when used, appears to create the problem or make
it worse.
If you need to transport or ship your EZCTP, package it carefully. We recommend
that you use the original container. If you are returning the unit, make sure you
include everything you received with it. Before you ship for return or repair, contact
Black Box to get a Return Authorization (RA) number.
Page view 0
1

Summary of Contents

Page 1 - BL A C K B O X

BL A C K B O X®Find problems in copper cables. EZ Check Cable Tester with ProbeEZCTP Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. c

Comments to this Manuals

No comments