Cable Specifications
The physical characteristics of the media cable must meet or exceed IEEE 802.3
specifications.
Copper cables
Category 3: (minimum requirement)
Gauge 24 to 22 AWG
Attenuation 11.5 dB/100m @ 5-10 MHz
Maximum cable distance: 100 m
Category 5: (recommended)
Gauge 24 to 22 AWG
Attenuation 22.0 dB/100m @ 100 MHz
Maximum cable distance: 100 m
• Straight-through or crossover twisted-pair cable may be used.
• Shielded (STP) or unshielded (UTP) twisted-pair cable may be used.
• Pins 1&2 and 3&6 are the two active pairs in an Ethernet network .
• RJ-45 Pin-out: Pin 1 = TD+, Pin 2 = TD-, Pin 3 = RD+, Pin 6 = RD-
• Use only dedicated wire pairs for the active pins:
(e.g., blue/white & white/blue, orange/white & white/orange, etc.)
• Do not use flat or silver satin wire.
Troubleshooting
If the transceiver fails, determine the answer to the following questions:
1. Is the status LED flashing?
NO
Verify that the AUI device is turned ON.
Verify that the AUI cable from the transceiver to the AUI device port is
installed properly.
Contact Tech Support: 724 746-5500.
YES
Go to step 2.
2. Is the RX LED flashing (receiving data)?
NO
Is the LED ON Solid?
Check twisted pair cable for proper connection
Contact Tech Support: 724 746-5500.
Yes
Go to step 3.
3. Is the TX LED ON?
NO
Check twisted pair cable for proper connection.
Is the LED flashing (transmitting data)?
Restart the hardware to force re-initialization.
Contact Tech Support: 724 746-5500.
Yes
Contact Tech Support: 1724 746-5500.
LE180A
10
Black Box Network Services, 724-746-550, www.blackbox.com Black Box Network Services, 724-746-550, www.blackbox.com
11
LE180A
Contact Us
Black Box, Headquarters
1000 Park Drive
Lawrence, PA 15055-1018
By Telephone: 877-877-2269
By Fax: 724-746-0746
By E-mail: [email protected]
Technical Support
Technical support is available 24 hours a day.
U.S.A: 724 746-5500
Fax: 800-321-0746
Website: www.blackbox.com/Tech_Support/Index.aspx#
Declaration of Conformity
Name of Mfg: Black Box Network Services
Black Box, 1000 Park Drive Lawrence, PA 15055-1018 U.S.A.
Model: LE180A Transceiver
Part Number(s): LE180A
Regulation: EMC Directive 89/336/EEC
Purpose: To declare that the LE180A Transceiver to which this declaration refers is
in conformity with the following standards.
EN55022:1998 + A1:2000 + A1:2003 EN 55024:1998 + A1:2000 + A2:2003
I, the undersigned, hereby declare that the equipment specified above conforms to the above
Directive(s) and Standard(s).
May, 2007_____
Stephen Anderson, Vice-President of Engineering Date
NETWORK SERVICES