Chapter 4: Installation
4. Installation
This chapter gives step-by-step installation instructions for the Hardened Ethernet Extender.
4.1 Selecting a Site for the Equipment
As with any electric device, you should place the equipment where it will not be subjected to extreme temperatures, humidity, or
electromagnetic interference. Specifically, the site you select should meet the following requirements:
• The surrounding air temperature should be between -40 to +167° F (-40 to +7 C).
The relative humidity should be less than 95 percent, noncondensing.
Surrounding electrical devices should not exceed the electromagnetic field (RFC) standards.
Make sure that the equipment receives adequate ventilation. Do not block the ventilation holes of the equipment.
The power outlet should be within 6 feet (1.8 meters) of the product.
4.2 Wiring Diagram
Field Wiring Terminal Markings: Use copper conductors only, 140° F/167° F (60° C/7 C) , wire range 12-24 AWG, torque value 7
lb-in.
Local mode
Remote mode
RJ-11 connector, twisted-
pair copper telephone line
RJ-45 connector,
twisted-pair copper wire
RJ-45 connector,
twisted-pair copper wire
Power 1, DC jack, 48 VDC
Power 2, terminal block, 24-48 VDC
Power 3, terminal
block, 24-48 VDC
Ground
Field wiring terminal:
Use copper
conductors only,
60/75° C, 12-24
AWG, torque value
7 lb.-in.
Power 3, terminal
block, 24-48 VDC
Power 3, terminal
block, 24-48 VDC
Ground
Power 1, DC
jack, 48 VDC
Figure 4-1. Wiring diagram using RJ-11 connector for copper telephone line.