Chapter 4: Installation
Local mode
Remote mode
Terminal block connector,
twisted-pair copper
telephone line
RJ-45 connector,
twisted-pair copper wire
RJ-45 connector,
twisted-pair copper wire
Power 1, DC jack, 48 VDC
Power 2, terminal block, 24-48 VDC
Power 3, terminal
block, 24-48 VDC
Ground
Field wiring terminal:
Use copper
conductors only,
60/75° C, 12-24
AWG, torque value
7 lb.-in.
Power 2, terminal
block, 24-48 VDC
Power 3, terminal
block, 24-48 VDC
Power 1, DC
jack, 48 VDC
Ground
Figure 4-2. Wiring diagram using terminal block connector for copper telephone line.
4.3 DIN Rail Mounting
Attach the DIN rail plate to the back panel of the Hardened Ethernet Extender.
Installation: Place the Hardened Ethernet Extender on the DIN rail from above using the slot. Push the front of the Hardened
Ethernet Extender toward the mounting surface until it audibly snaps into place.
Removal: Pull out the lower edge and then remove the Hardened Ethernet Extender from the DIN rail.
Figure 4-3. DIN rail plate attached to back panel of the extender.
4.4 Connecting to Power
Redundant DC terminal block power inputs or 48 VDC DC jack:
4.4.1 Redundant DC Terminal Block Power Inputs
There are two pairs of power inputs that you can use to power up this device. You only need to have one power input connected
to run the Hardened Ethernet Extender.