Chapter 4: Installation
Step 1: Connect the DC power cord to the pluggable terminal block on the Hardened Ethernet Extender, and then plug it into a
standard DC outlet.
Step 2: Disconnect the power cord if you want to shut down the Hardened Ethernet Extender.
4.4.2 48-VDC DC Jack
Step 1: Connect the supplied AC to DC power adapter to the receptacle on the top side of the Hardened Ethernet Extender.
Step 2: Connect the power cord to the AC to DC power adapter and attach the plug into a standard AC outlet with the
appropriate AC voltage.
Figure 4-4.
Table 4-1. Power Input Assignment.
Power Signal Voltage Connector
Power 1 48 VDC DC jack
Power 2
+ 2448 VDC
Terminal block
- Power Ground
Power 3
+ 2448 VDC
- Power Ground
Earth Ground
Table 4-2. DIP switch settings.
DIP switch Description
Loc The device operates in local mode.
Rmt The device operates in remote mode.